Proper Roof System Installation

Procedure of Roof system Installation


Laying of sheets


when laying the bitumen sheets- always start from the bottom corner of the

roofing, on the opposite direction of prevailing winds. It must be parallel to the

eaves, moving up in steps towards  the ridge (Illustration #1 )


























OVERLAPPING




Side Lap :     One corrugation

Head Lap:     15cm









FIXING THE SHEETS





Installed bitumen sheets  are secured using zinc- plated nails -GUTTANIT

Two rows of nails are driven in, parallel to the diretion of the head up at the end

of each side of the sheets, always inserted fom the top of each corrugation.  all

rows of nails are set up in every third corrugation-  secured and sealed through

the top of the corrugation.