INSTALLATON - CORRUGATED ACRYLIC SHEET 1.5 mm
INSTALLATION
Roof pitch 10" (minimum 7")
Substructure should be made of wooden slats 40 x 60 mm or metal.
The gab between the slats max of 80 cm for slats of standard load capacity
A silver self- adhesive tape should be pasted on the crossbars.
Drill holes on the ridge. use a special plastic drill the diameter of the holes has to be 4-5 mm wider than the diameter of the screws to allow space for expansion when the roof is exposed to the heat.
Lateral overlapping : one corrugation for pitch of 10" and two corrugation for the pitches less than 10"
Longitudinal overlapping:15cm, and for the pitches less than 10" 20 cm.
Screws every 3rd wave crest, and on the crest of each corrugation in the edge region.
Installation with spacers on every screw
10-15 screws per m2. For every screw a spacer is necessary
If necessary use additional accessories.